PRODUCTS
No data
Product Details
Product Description
High-Voltage Short Circuit Test & Intercell Welding Machine
This machine is mainly used for high-voltage short-circuit testing, intercell welding and weld resistance testing of lead-acid batteries.
Technical Parameters
- Main application: High‑voltage short‑circuit test, intercell welding and weld resistance test for lead‑acid batteries
- Applicable battery size: Adaptable to customer-specified battery models
- Production capacity: Matches the throughput requirement of the whole production line
- Power supply: 380V/50Hz, Power: 80 kW
- Air supply: 0.5–0.8 MPa, Air consumption: 50 L/min
- Overall dimension (L×W×H): 4110 × 1450 × 2100 mm
- Conveying speed: 220 mm/s
- Worktable height: 750 ±30 mm
- Working stations: Three processes (high‑voltage short‑circuit test, two welding stations, resistance test and rejection)
- Running direction: From left to right
- Weld pin insertion depth into battery housing meets the requirement of specified models
- Cooling water flow & pressure: 2.5 L/min, 0.2 MPa
- Max. welding current: 12000 A
- Max. welding time: 9.9 s
Mechanical & Functional Features
- High‑voltage short‑circuit test voltage: 0–3000 V pulse
- High‑voltage short‑circuit test current: 0–500 mA
- High‑voltage short‑circuit test duration: 0.1 s–0.5 s
- High‑voltage short‑circuit test points: 12 test probes, 6 cells tested separately for short circuit
- Medium-frequency DC welding is adopted for more stable welding current and better welding quality
- The conveyor chain is stainless steel slat chain for long service life
- Equipped with transformer and microcomputer controller, it delivers stable output current and voltage, low instantaneous impact on power grid, high control precision. Its welding quality and reliability outperform conventional transformers.
- LCD screen displays parameters for convenient, clear and intuitive adjustment
- Weld resistance test voltage: 5 V DC
- Weld resistance test current: 10–100 A
- Weld resistance test duration: 0.1 s–9.9 s or continuous mode
- Weld resistance test points: 10 high‑voltage probes, 10 resistance measuring points
- Automatic feeding, testing, rejection and discharging. Defective batteries are automatically ejected
- Probe testing, easy, safe and efficient operation; no damage to batteries
- Fully enclosed operation, unattended running
- Motion control system: Driven by pneumatic components and motors. Controlled by PLC programming with touchscreen HMI. It supports equipment operation, parameter modification and storage. Fault alarm points are displayed on the touchscreen, accompanied by flashing alarm lights.
Intention message